40950363
tender for provision of certain cap / mr / mw works under age br ( i ) ( ii ) and age ( e / m ) at af station bhuj; 1 demolitionof unreinforced cement concrete of any description and any position not otherwise specifically provided for complete all as specified and directed by engineer in charge. 2 dismantling wrought iron or mild steel work of any description not otherwise specifically provided for complete all as specified and directed by engineer in charge. 3 excavating over area n. exc. 1.5m deep and getting out in hard / dense soil complete all as specified and directed by engineer in charge. 4 material & labour for plain cement concrete, type d2, ( 1:4:8 ) , ( using 40mm graded stone aggregate ) in foundationand filling mass concrete complete all as specified and as directed byengineer in charge. 5 formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits ( if any ) of foundation and plinth beams;and similar work; vertical or to batter complete all as specified and directed by engineer in charge. 6 formwork to faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to better etc complete all as specified and directed by engineer in charge. 7 formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick ( horizontal or sloping ) complete all as specified and directed by engineer in charge. 8 material & labour for m 30 reinforment cement concre foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and directed by engineer in charge. 9 material & labour for rcc m 30 ( design mix ) in walls, retaining walls, basement walls, ballast wall and the like any thickness, above top of footings including attached plasters and buttresses etc complete all as specified and directed by engineer in charge. 10 material & labour for m 30 reinforment cement concre slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by engineer in charge. 11 material & labour for tmt bars 10mm dia and over, cut to length, bent to shape required, including crancking, bending spiraly for column & hooping ends and binding with and including mild steel wire ( annealed ) not less than 0.9 mm dia complete all as specified and directed by engineer in charge. 12 returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick complete all as specified and directed by engineer in charge. 13 removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points complete all as specified and directed by engineer in charge. 14 material & labour for precast cement concrete block masonry with solid blocks exc 10cm in width type c1 ( 1:3:6 ) ( using 20mm graded stone aggregates ) and setting in cement mortar 1:6complete all as specified and as directed byengineer in charge. 15 material & labour for 10 mm thick rendering for fair faces of concrete surfaces on walls in cm 1:6 and finished even and smooth without using extra cement complete all as specified and directed by engineer in charge. 16 material & labour for preparing new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed by engineer in charge. 17 demolition of brick work or stone / boulder / block masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by engineer in charge. 18 material & labour for cement concrete type b 1, 1:2:4 ( using 20mm graded aggregate ) as in bed blocks for fixing of hold fasts including rendering 15 mm thick with cm 1:6etc complete all as specified and directed by engineer in charge. 19 material & labour for rendering 15mm thick in cm ( 1:4 ) on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement, complete all as specified and directed by engineer in charge. 20 supply & fix framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides ) and hanging; also fastening and fixing complete all as specified and directed by engineer in charge. 21 supply & fix collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets complete all as specified and directed by engr in charge. 22 material & labour for preparing new or previously untreated steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide or zinc chrome primer on steel surfaces complete all as specified and directed by engineer in charge. 23 cutting upto a depth of 2.5 cm into concrete walls and trimming surfaces as required girth exc 30 cm complete all as specified and directed by engr in charge. 24 material & labour for sub main wiring with two runs ( two runs measured as one run ) of pvc insulated and unsheathed frlsh cable 650 / 1100 volts grade, conforming to is 1536 1977 multi stranded 4 sqmm single core, copper conductor drawn through and including pvc casing capingisi marked with accessories to wall / ceiling with proper saddles and 4 sqmm single core multistranded copper conductor frlsh pvc insulated and unsheathed cable 1100 volts grade, isi marked as earth continuity wire complete all as specified and directed by engr in charge. ( note: two runs of conductor with one run of earth wire and one run of conduit will be measured & paid as one unit ) 25 supply & fix switch socket combination 2 in 1, 6 / 16a flush type 2 modular isi marked complete all as specified and directed by engineer in charge. 26 supply & fix pvc rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed by engineer in charge. 27 supply & fix double door sheet metal enclosures factory made dbsprotection class ip 43, suitable for fixing of mcbs, isolators etc, confirming to is 13032 single pole and neutral 4 ways with 200 amp rated bus bar 240 volts powder coated complete all as specified and directed by engr in charge. 28 supply & fix isolators / mcbs, etc. in distribution board of the following rating and capacities complete all as specified and directed by engineer in charge. 29 mcb spn of 240 volts 20 / 32 / 40 amps capacity, c series, 10 ka 30 mcb sp of 240 volts 6 40 amps capacity, c series, 10 ka 31 mcb tpn of 415 volts 63 amps capacity, c series, 10 ka 32 material & labour for 25 mm thick cement concrete type b 0, 1:2:4using 12.5mm graded aggregate insub base of floors etc complete all as specified and directed by engineer in charge. 33 material & labour for vitrified ceramic light shade 10 mm thick ( sqaure / rectangular ) area of each tiles n.exc. 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match existing tiles and including 15 mm thick screed bed or bedding layer of mortar 1:6 for laying floor finishes complete all as specified and directed by engineer in charge. 34 all as per item no 30 but in vertical surfaces such as dado, skirting and riser including rendering 10 mm thick in cm 1:4 complete all as specified and directed by engineer in charge. 35 complete removal of existing treatment on wall surfaces and applying two coats of distemper with distemper oil emulsion, white or tinted including one coat of wall care putty by finishing the surfaces even and smooth complete all as specified and directed by engineer in charge. 36 material & labour for preparing new plastered surfaces of walls and applying two coats of acrylic washable distemper over a coat of chalk whitening complete all as specified and directed by engineer in charge. 37 material & labour for rendering 15mm thick in cement mortar 1:4 ( external ) on brick walls or on concrete surfaces in two coats, 1st coat of 10mm thick and 2nd coat of 5mm thick including mixing with wpc to 2nd coat as per manufacturers instructions, plastered surfaces finished even and smooth without using extra cement, complete all as specified and directed by engineer in charge.note : integral water proofing compound shall be measured and paid separately as ‘supply only’ under relevant items. 38 material & labour for preparing new surfaces of walls and applying two coats of cement base paint over one coat of priming plastered and other surfaces with alkaliresistand priming paintcomplete all as specified and directed by engineer in charge. 39 taking down chowkats or frames with shutters ( without taking off shutters from the frames ) exc. 1.5 sqm but not exc. 4.00 sqmeach complete all as specified and directed by engineer in charge. 40 refixing in the same opening of chowkhat or frames with shutters ( without taking off shutters from the frames ) exc. 1.5 sqm but not exc. 4.00 sqm eachcomplete all as specified and directed by engineer in charge. 41 taking down cement plaster of any description on brick walls, concrete surfaces including racking out joints, hacking for key, scrubbing down with water remove dust, debries / rubbish etc complete all as specified and directed by engineer in charge. 42 material & labour for 20mm thick granite work ( table rubbed and polished ) in steps, jambs, pillars, window cills, cooking platforms and like including 20mm thick screed bed of cement mortar ( 1:4 ) including pointing in white cement ( 1:2 ) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by engineer in charge. note : cost of screed bed shall deemed to be included in quoted unit rate . 43 supply and install hi wall split units indoor / outdoor of air conditioner complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and eer 3.2.of capacity 1.0 ton complete all as specified and directed by engineer in charge. 44 supply & fix voltage stabilizer electronic wall mounting type suitable for ac upto 1.0 tr for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stablized at 230 v with accurancy of + 2.5% and of capacity 3.0 kva complete all as specified and directed by engr in charge. 45 supply & fix in replacement metal clad enclosure pole and neutral with a two pin and earth plug and socket complete 240 volt with one single pole mcb of 20 amps complete all as specified and directed by engr in charge. 46 supply & fix mcb spn in distribution board of the rating of 5 to 32 amps capacity, c series, 10 ka complete all as specified and directed by engr in charge. 47 excavating in post holes ( or similar holes ) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm watering, and removing surplus soil to a distance n exc 50 m and making good surface in hard / denses soil complete all as specified and directed by engr in charge. 48 material & labour for pcc1:2:4, b2 ( using 40mm graded stone aggregate ) infoundations filling and mass concrete complete all as specified and directed by engineer in charge. 49 supply & fix roof trusses ( framed ) , trussed, posts, purlins, crane gantries, rails and fastenings and heavy bracket framing ( beam, tee, angle, channel, retangular / square tubes or flat sections ) including distance pieces, cleats etc fe 410 w ( gde / e 250 ) quality a complete all as specified and as directed byengineer in charge. 50 dismantling frames trusses not exc 10 m length complete all as specified and directed by engr in charge. 51 dismantling plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof coverings etccomplete all as specified and directed by engr in charge. 52 supply & fix pre painted galvatume aluminum zinc coating gi based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed by engineer in charge. 53 fixing only pre painted galvatume aluminum zinc coating gi based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed by engineer in charge. 54 supply & fix mild steel for wind ties of size 25mm x 5mm for roof including securing bolts , incuding cutting tops to shape as directed , drilling holes and similar works conforming to fe 290 gde e 165 complete all as specified and directed by engineer in charge. 55 material & labour for preparing old or previously untreated steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer on steel surfaces complete all as specified and directed by engineer in charge. 56 supply & fix ms bed plate any thickness with sleeve pieces riveted or welded complete all as specified and directed by engineer in charge. 57 erection and fixing only steel work in tubular trusses including special shaped washer etc. complete using erw or induction butt welded tubes conforming to i. s.1161 1979 grade st. 240 complete all as specified and directed by engineer in charge. 58 supply & fix in repairs mild steel screw bolts 5 to 10 mm dia of neck ( machine made ) with hexagonal or square heads at one end and screwed theother, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm longcomplete all as specified and directed by engineer in charge. 59 welded steel wire fabric not exc. 4.00 kg supplied & fixed complete to wood of steel members complete all as specified and directed by engineer in charge. 60 excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in soft / loosesoil soil complete all as specified and directed by engineer in charge. 61 supply & fix mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets ( for securing wire mesh etc. ) including all necessary drilling, bolting or riveting, etc and similar work conforming to fe 290 gde e 165 complete all as specified and directed by engineer in charge. 62 supplied & fixed mild steel round bars 10 mm dia and over as in strengthening bars for chain link fencing conforming to fe 290 gde e 165complete all as specified and directed by engineer in charge. 63 supply only chain link ms galvanised fencing of 3.15 mm dia of wire and 40 mmx40mm mesh size ( pitch of wires ) conforming to is 2721:2003 including line wires of 4 mm dia straining bolts, etc including provision of binding wire complete all as specified and directed by engineer in charge. 64 fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc ncluding provision of binding wire complete all as specified and directed by engineer in charge 65 supply & fix in repair galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed ( each line wire to be measured ) incl dismantling of old fencing complete all as specified and directed by engineer in charge. 66 material & labour for m 30 reinforment cement concre for columns, pillars, piers, posts and struts complete all as specified and directed by engineer in charge. 67 removing excavated materials at a distance exc. 500 m but n.exc. 1.50 mtr and depositing / spreading and leveling where directed at a level n.exc. 1.5m above the starting points complete all as specified and directed by engineer in charge. 68 formwork to sides of pillars, posts, struts, piers, columns and stanchions of retangula / square for rough finished surfaces of concrete etc complete all as specified and directed by engineer in charge. 69 material & labour for mild steel tmt bars 5mm dia, cut to length, bent to shape required, including cranking, stirrups spaces and bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire ( annealed ) not less than 0.9mm dia or securing with clipsetc complete all as specified and directed by engineer in charge. 70 material & labour for framed work such as grills, gratings, etc.. with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; hung as gates, including pintle hinges, stops, hand made sliding bolts, etccomplete all as specified and directed by engineer in charge. 71 material & labour for framed work such as grills, gratings, etc.. with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; hung as gates, including pintle hinges, stops, hand made sliding bolts, etccomplete all as specified and directed by engineer in charge. 72 material & labour for 5 mm thick rendering for fair faces of concrete surfaces on ceiling in cm 1:3 for fair finished surfaces even and smooth without using extra cement complete all as specified and directed by engineer in charge. 73 supply & fix ms framed work by fabrication such as grills, gratings, etc.. with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framed work of water tanks etcincluding portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc conforming to fe.290.gde e 165complete all as specified and directed by engineer in charge. 74 supply & fix ms purpose made butt hinges conforming to fe 290 gde e 165 suitable for fixing to stone / concrete door and window frames including fabrication work etccomplete all as specified and directed by engineer in charge. 75 supply , laying and testing cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty ) 1100 volts grade with stranded aluminium conductor complete all as specified and directed by engineer in charge for the following size of size: 76 120 sqmm 3.5 core 77 50 sqmm 3.5 core 78 10 sqmm 2 core 79 excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in hard / dense soil soil complete all as specified and directed by engineer in charge. 80 material & labour for sand cushioning for ug cables using dry river sand; gently punning down complete all as specified and directed by engineer in charge. ( note : for measurement purpose punned thickness shall be considered ) 81 supplying and laying un reinforced precast concrete cable cover class lv, type 2, flat, size 300x 180 x 40 mm complete all as specified and directed by engineer in charge. 82 material & labour for straight through joint ( epoxy ) for lt 1100 volts grade, aluminium conductor jointing kits, aluminium ferrules and labour complete for making joints and testing complete for cable size 70 to 120 sqmm, 4 corecomplete all as specified and directed by engineer in charge. 83 material & labour for cutting of existing road for laying gi pipe of size 50 mm including pcc work after laying the cable in gi pipe complete all as specified and directed by engineer in charge. 84 supply & fix tubes light grade of 80 mm bore galvanised with all fitting for cable protection trenches / wall / on pole including necesarry clamps sets and nut & bolts etc complete all as specified and directed by engineer in charge. 85 material & labour for wall mounted fan 400 mm sweep, 240 volts osillation type sturdy & heavy dutypvc blades for higher air dilivery, nickel chrom plated guard, smooth oscillation complete in exisiting wall etc complete all as specified and directed by engineer in charge. 86 material & labour for point wiring complete with 1.5 sqmm single core multistranded copper conductor pvc insulated and unsheathed frlsh cable 1100 volts grade isi marked drawn through and including pvc casing & capping including accessories etc including fixed to wall / ceiling including provn of 1.5 sqmm single core multistranded copper conductor frlsh pvcinsulated and unsheathed as earth wire continuity with and pressed steel terminal box powder coated of suitable size 3mm thick bakelite white / colour sheet top cover isi marked with brass screws and cup washers for housing switches, sockets, fan regulator, one fan / exhaust point controlled by one, one way switch single pole etc complete all as specified and directed by engineer in charge. 87 material & labour for modular switch 1 way 6a 1 modulecomplete all as specified and directed by engineer in charge. 88 supply & fix modular socket 6a 5 pin 2 in 1 combined 2 module 240 volts complete all as specified and directed by engineer in charge. 89 supply & fix modular white cover plate with frame of 3 moduler isi marked complete all as specified and directed by engineer in charge. 90 supply & fix modular surface mounting plastic box of 3 moduler isi marked complete all as specified and directed by engineer in charge. 91 supply & fix steel work in tubular trusses including special shaped washer etc. complete using erw or induction butt welded tubes conforming to i. s.1161 1979 grade st. 240 complete all as specified and directed by engineer in charge. 92 supply & fix plates ( plain or chequered ) channels, square cut or notched ( ordinary and counter sunk ) forming holes, without any attachment complete all as specified and directed by engineer in charge. 93 surface excavation n. exc 30cm deep and averaging 15cm deep and getting out in hard / dence soil complete all as specified and directed by engineer in charge 94 rolling and consolidation formation surfaces in cutting using power roller exc 8 tonne but n exc 12 tonne complete all as specified and directed by engineer in charge. 95 material & labour for hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surfacecomplete all as specified and directed by engineer in charge. 96 material & labour for 100 mm thick cement concrete type c2, 1:3:6using 40mm graded stone aggregate insub base of floors etc complete all as specified and directed by engineer in charge. 97 material & labour for 100 mm thick cement concrete type b1, 1:2:4using 20mm graded stone aggregate as in floors etc complete all as specified and directed by engineer in charge. 98 forming contraction ( dummy ) joints 65mm deep x 10mm wide, filled with sealing compound grade b complete all as specified and directed by engineer in charge. 99 material & labour for point wiring complete with 1.5 sqmm ( nomonal area ) pvc insulated pvc unsheathed multistranded copper conductor single core cable 1100 volts grade frlsh isi marked drawn through and including heavy duty non metalic pvc conduit isi marked not less than 20 mm dia of thickness 1.8 mm concealed in wall roof etc with all connected fittings including pressed steel terminal boxes suitable for mounting modular switches sockets etc and including pvc insulated and unsheathed multistranded single core copper conductor cable of size 1.5 sqmm green in colour as in earth continuity conductor connected to common earth dolly and all metal parts of fittingscomplete all as specified and directed by engineer in charge for: . 100 one light point controlled by one, one way switch single pole. 101 one exhaust fan point controlled by one, one way switch single pole. 102 one 3 pin 5 amps socket out let on independent board. 103 all as per item no.93 here in before but with 2.5 sqmm copper conductor cable for one 3 pin, 15 amps socket out let on independent board complete all as specified and directed by engineer in charge. . 104 supply & fix in replacement of ceiling rose 3 phase, pvc / polycarbonate body complete all as specified and directed by engr in charge. 105 supply & fix modular plastic surface box of module 1 / 2 flush isi marked complete all as specified and directed by engineer in charge. 106 supply & fix modular plastic surface box of module 3 flush isi marked complete all as specified and directed by engineer in charge. 107 supply & fixingin repairs wall mounted decorative ultra slimled lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack instant start with uniform light distribution 20 w 4 ft indoor decorative with 2 core copper wire from ceiling rose to light fitting complete all as specified and directed by engr in charge 108 supply & fix modular white cover plate with frame of module 1 flush isi markedcomplete all as specified and as directed byengineer in charge. 109 supply & fix modular white cover plate with frame of module 3 flush isi markedcomplete all as specified and as directed byengineer in charge. 110 supply & fix modular blank plate module 1 complete all as specified and as directed byengineer in charge. 111 supply & fix modular switch flush type, 6 amp. sp, one way , 1 module complete all as specified and as directed byengineer in charge. 112 supply & fix modular socket outlet, 3 pin, 6 amp, flush type 2 module complete all as specified and as directed byengineer in charge. 113 supply & fix modular switch 16 amp, flush type 1 module complete all as specified and as directed byengineer in charge 114 supply & fix modularsocket outlet, 3 pin, 6 / 16 amp flush type 2 module complete all as specified and as directed byengineer in charge. 115 material & labour for earthing complete with galvanised steel earth plate electrode 60cmx60cm x 6 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised earth lead wire 4.0mmdia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate no. 3 connected to earthing test point all as specified or indicated including testing on completion provn of gi protectionpipe light grade of 32mm bore upto 7.5m length and connected earth wire to earthing test point all as shown in electrical plate no. 3 of ssr part i 2009 and as specified or indicatedand testing on completion including necessary excavation & earthwork in any type of soil, pcc ( 1:3:6 ) type c1 chamber, precast slab 50mm thick in cement concrete ( 1:2:4 ) type b1 ( rein forced with welded steel wire fabric ( xpm ) of weight not less than 4kg / sqm ) with frame, funnel with watering pipe of 20mm bore medium grade, wire mesh and lugs test point etc complete all as specified and as directed byengineer in charge. 116 supply & fix distribution board ( db ) double door type made out of sheet metal enclosures ( crca ) dust and vermin proof db tpn 4 way with 200 amps rated copper bus bar 415 volts with in built mccb 63 amps 16 ka 1 no each bar ip 43 protection fix flush to wall complete all as specified and directed by engr in charge. 117 supply & fix switch piano flush type, 230 / 250 volts 5 amp. sp, one way complete all as specified and directed by engr in charge. 118 supply & fixswitch socket combination 2 in 1, 5 / 15a amp flush type isi marked complete all as specified and directed by engr in charge. 119 supply & fix exhaust fan, steel body ac single phase 230v of size 300 mm sweep with blades and frame and louvers complete all as specified and directed by engr in charge 120 supply & fixing led light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 v ac decorative type with driver holder and led lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed byengineer in charge. 121 supply & fixing led lights fitting 1x 20w, 220v, ac decorative box type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed byengineer in charge. 122 supply & fix energy saving evironmental friendly long life corrosion resistent impact proof surface mounted luminaire with pc housing & opel finish cover suitable for wet location with led 25 w light source including material and labour 32 mm dia light grade gi pipe bracket with ms clamps complete with nuts and bolts and washers complete all as specified and as directed byengineer in charge 123 supply & fixing amp rating 240v, 10ka c curve miniature circuit breaker ( mcb ) of following poles and current carrying capacity in the mcb db complete with connection testing and commissioningcomplete all as specified and directed by engineer in charge for: . 124 mcb sp 5 to 40 amps 125 mcb spn 32 amps 126 supply & fixing including testing of storage type water heater / geyser of vertical type of capacity 25 ltr, rated 2000w, 230v ac, 50hz auto cutoff with a high tech adjustable thermostat, multifuction saftey valve, powder coated metal body glass lined enamel coated tank material advanced puf insulation magnesium anode coated heating element, red and green indicator lamp, suitable for highrise building suitable for water pressure head upto 8 bars , star rating ( bee ) 5 star high density & thick puf that ensures energy efficiency and reduced electricity bills 15 amps heavy duty plug complete all as specified and directed by engineer in charge 127 supply & fixing cpvc pipes 20mm dia sdr 11 & plain cpvc sdr 11 with all fittings on wall / ceiling complete all as specified and directed by engineer in charge 128 supply & fixing geyser pvc connection 15mm size with ptmt nuts of length 450mm long complete all as specified and directed by engineer in charge 129 supply & fix bib taps, cast copper alloy fancy typechromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for size15mm bore complete all as specified and directed by engineer in charge. 130 supply & fix stop valve 15mm dia cast copper alloy fancy type chromium plated screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by engineer in charge. 131 material & labour for 25 mm bore galvanised steel tubing medium grade isi marked with all fitting and fixed complete to walls and ceiling or laid in floor / trenches and under road complete all as specified and directed by engineer in charge 132 material & labour for cutting existing steel tubing for alterations or additions of size mm bore complete all as specified and directed by engineer in charge 133 supply & fix gun metal globe / forged valve withiron wheel head screwed both ends for joining iron pipe non rising forged brass spindle class 1 is 778 marked of 25 mm size complete all as specified and directed by engineer in charge. 134 supply & fix 25 mm bore galvanised iron tubes light grade for cable protection complete all as specified and directed by engineer in charge 135 supplying and laying un reinforced precast concrete cable cover class lv, type 1, flat, size 250x 180 x 40 mm complete all as specified and directed by engineer in charge. 136 earth work in excavation by mechanical means ( hydraulic excavator ) means over areas ( exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan ) n exc 1.5 m deep including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m complete all as specified and directed by engineer in charge. 137 earth work in excavation by mechanical means ( hydraulic excavator ) means over areas ( exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan ) exc 1.5 m but n exc 3.00 deep including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m complete all as specified and directed by engineer in charge. 138 formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed by engineer in charge. 139 material & labour for m 30 reinforment cement concrete beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by engineer in charge. 140 material & labour for m 30 design mix reinforment cement concrete as in chajja complete all as specified and directed by engineer in charge. 141 material & labour for 40 mm thick cement concrete type b 0, 1:2:4 mix ( using 12.5 mm graded stone aggregates ) as in dpc or copings to horizontal or vertical surfacesincludingnecessary use and waste of form work complete all as specified and directed by engineer in charge. 142 material & labour for pcc 1:3:6 type c 0 ( using 12.5 mm graded stone aggregate ) as in roof padding complete all as specified and directed by engineer in charge. 143 material & labour for rendering 10mm thick over rcc roof mixed , in cement mortar 1:3 mixed with integral water proofing compound at the rate of minimum @ 3% by weight of cement and as per manufacturers instructions, finished even and smooth without using extra cement complete all as specified and directed by engineer in charged. ( supply only water proofing compound shall be measured and paid for separately ) 144 priming surfaces and applying normal treatment ( for moderate conditions ) using glass fibre base bitumen felt, grade 2 complete all as specified and directed by engineer in charge. 145 app based polymeric membrane minimum weighing 3kg / sqm and minimum 3mm thick reinforced with polyster non wove fabric ( wt. not less than 150 gms / sqm ) land on primed surface by forced application complete all as specified and directed by engineer in charge. 146 material & labour for cement concrete 1:3:6 ( using 40mm stone graded aggregate ) , 75mm thick as in plinth protection, etc., laid in alternate bays, finishing concrete surfaces even and smooth without using extra cement, complete all as specified and directed by engineer in charge. 147 material & labour for rendering 15mm thick in two layers first coat 10mm thick in cm 1:6 and second coat 5mmthickin cm 1:4 with wate proofing compound @3% by wt of cement on fair faces of brick work or concrete surfaces, finished even and fair complete all as specified and directed by engineer in charge. note : wpc will be measured and paid separately. 148 supply only water proofing compound complete all as specified and directed by engineer in charge. 149 material & labour for preparation of new surfaces of wall and applying two coats of exterior emulsion paint camoflage pattern paint over a coat of wall primer complete all as specified and directed by engineer in charge 150 material & labour for preparing new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by engineer in charge. 151 supply & fix anodised aluminium frame powder coated for ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by engineer in charge. 152 supply & fix anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg / m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long ( 1 no. ) . hinges type b 21 100mm long ( 2 no. ) suitable handle ( 1 no. ) complete all as specified and directed by engineer in charge. 153 supply & fix sheet glass 4mm thick, ordinary quality and glazing with putty in squares nexc 0.5 sq. m in each pane complete all as specified and directed by engineer in charge. 154 material & labour for treating the backfill in contact withfoundation @ of 7.5 litres ofemulsion per square metre of vertical surface layer of the sub structure in contract with back fill to be measured complete all as specified and directed by engineer in charge. 155 material & labour for treating the top surface of filled earth @ 5 litres chlorophyrophase of emulsion per square metre of surface complete all as specified and directed by engineer in charge. 156 material & labour for treating the soil under plinth protection @ 5 litreof emulsion per square metre of surface area complete all as specified and directed by engineer in charge. 157 supply & fix solid pvc door frame of size 50mm x 47mm made out of 5mm plain colour pvc sheet reinforced with m.s. square tube, suppling & fixing in opening complete all as specified and directed by engineer in charge. 158 supply & fix factory made solid panel pvc door shutter 30 mm thick ( style ) consisting of frame made out of m.s. tubes for top & bottom rails. m.s. frame shall be covered with heat moulded plain colour pvc ‘c’ channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour pvc sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour pvc sheet to be fitted in the m.s. frame welded / sealed to the stiles & rails with suitable pvc sheet beading, and joined together with solvent cement, suppling & fixing in the frame, complete all as specified and directed by engineer in charge. 159 supply & fix 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple ( bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed by engineer in charge. 160 supply & fix aluminium anodised, barrel tower bolts of extruded section length of bolt 150 mm complete all as specified and directed by engineer in charge. 161 supply & fix aluminium handle cast type anodized 150 mm complete all as specified and directed by engineer in charge 162 supply & fix ms butt hinge medium weight cold rolled 100 mm size complete all as specified and directed by engineer in charge. 163 supply & fix vitreous china wash down water closet pan ( pedestal pattern ) , white ( excluding fixing bolts, flushing cistern and flush pipe ) complete all as specified and directed by engineer in charge. 164 supply & fix 10 litres, cast iron, valveless. syphonic action type, flushing cistern, high level with inlet, ball valve, float, chain and pull, and bracketscomplete all as specified and directed by engineer in charge. 165 supply & fix seat and cover for pedestal pan complete all as specified and directed by engineer in charge. 166 supply & fix flush pipes to pedestal pan including all joints complete all as specified and directed by engineer in charge. 167 supply & fixing 1000 litre capacity rotational moulded polythelene water storage tank isi marked, cylindrical vertical with closed top hoisted and fixed in position all specified in ssr part i orcomplete all as specified and directed by engineer in charge. 168 material & labour for 20 mm thick screed bed or bedding layer of cement mortar 1:6 for laying floor finishes complete all as specified and directed by engineer in charge. 169 material & labour for non skid ceramic tiles 7 to 8mm thick ( sqaure / rectangular ) area of each tiles exc. 0.06 sqm but n.exc. 0.11sqm as per is 13755 in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by engineer in charge 170 material & labour for 10 mm thick screed bed in cement mortar 1:4 to receive tiles etc on vertical surface of walls complete all as specified and directed by engineer in charge. 171 material & labour for glazed tiles 200mmx300mmx7mm thick in as in skirting / dados set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles complete all as specified and directed by engineer in charge. 172 supply & fixing pvc connection 15mm size with ptmt nuts of length 600mm long complete all as specified and directed by engineer in charge 173 supply & fix brass chromium plated tubular towel rail 20 mm dia d type 60 cm long between flanges complete all as specified and directed by engineer in charge. 174 material & labour for 15 mm bore galvanised steel tubing medium grade isi marked with all fitting and fixed complete to walls and ceiling or laid in floor complete all as specified and directed by engineer in charge 175 material & labour for 20 mm bore galvanised steel tubing medium grade isi marked with all fitting and fixed complete to walls and ceiling or laid in floor complete all as specified and directed by engineer in charge 176 supply & fix stop valves, 20 mm ( isi marked ) cast copper alloy, screwed down, high pressure, with but but fancy type, chromium plated with long shank and cup ( concealed type ) complete all as specified and directed by engineer in charge. 177 supply & fix ball brass valves, high pressure, with polyethylene float and flynutcomplete, screwed for iron pipe or brass ferrule and fixed bore of pipe 20 mm size complete all as specified and directed by engineer in charge. 178 supply & fix bevelled edge mirror of size 600mm x 450mm selected quality glass mounted on6mm thick ac building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washer complete all as specified and directed by engineer in charge. 179 material & labour for pvc ( swr ) gully trap 125 / 110mm, settingand jointing with solvent cement complete all as specified and directed by engineer in charge 180 supply & fix vitreous china wash basin, white flat back, size 550x400mm , excluding taps, waste, chain and plug and porcelain stopper including brackets complete all as specified and directed by engineer in charge. 181 material & labour for32 mm bore waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed complete all as specified and directed by engineer in charge. 182 supply & fix pillar taps of 15 mm bore, fancy type cast copper alloy with capstan head, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly nuts, screwed for iron pipe & fixed complete all as specified and directed by engineer in charge. 183 material & labour for cast iron nahani trap, of 75 mm grating including jointing to waste pipe fixed in cement concrete type b 1 ( 1:2:4 ) complete all as specified and directed by engineer in charge. 184 supply & fix 100 mm bore sand cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed by engineer in charge. 185 supply & fix soap dish any type fixed to plugs with chromium plated brass screws complete all as specified and directed by engineer in charge. 186 supply & fix vitreous china urinals, bowl flat back size 465x355x265 mm ( white ) with grating and unin for discharge pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement;complete all as specified and directed by engineer in charge. 187 supply & fix angle stop valve of ptmt any colour high pressure screwed for iron pipe and fixed, ( minimum weight 15mm 90gms ) complete all as specified and directed by engineer in charge 188 material & labour for 50 mm thick cement concrete type b 1, 1:2:4 mix ( using 20 mm graded stone aggregates ) as in copings includingnecessary use and waste of form work complete all as specified and directed by engineer in charge. 189 material & labour for providing precast reinforced cement concrete type b 1, 1:2:4 ( using 20mm graded stone aggregate ) as in cover slabs for man holes and set in cement mortar ( 1:4 ) including necessary form workcomplete all as specified and directed by engineer in charge.note: reinforcement steel shall be measured and paid separately 190 material & labour forproviding cement concrete 1:3:6type c 2 ( using 40mm graded stone aggregate ) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for size 200 mm bore of pipe complete all as specified and directed by engineer in charge. 191 material & labour for sail glazed stone ware drain pipes grade a isi marked laid to slope in trenches and jointed in cm ( 1:2 ) and tested complete size 200 mm bore complete all as specified and directed by engineer in charge. 192 material & labour for plain cement concrete, type b2, ( 1:2:4 ) , ( using 40mm graded stone aggregate ) in foundationand filling mass concrete complete all as specified and as directed byengineer in charge....
Due Date : December 23, 2023
Tender Value : ₹ 25.10 Lakhs